Looking to design a simple 2 pipe system so one VFD controlled heat pump can run 2 evaporator coils. The evaporator coils are EXV controlled with independent controls for each coils superheat. I would like to be able to run them independently so either one or both coils can run as needed. I do not want the ability to heat and cool at the same time, so the system will be in heat mode or cool mode. On the cooling side the exv valve could probably use it to control the flow but when in heating mode I want to control the flow of the liquid side so I only provide heat tot he unit running. The 2 coils are only 8 feet apart so the piping of the combined liquid and suction lines will be pretty easy. Since I am only wanting one mode available, either heating or cooling, can it be as simple as just installing a NC solenoid valve on the liquid line to each coil before the EXV valve and after the separation tube? Or am I missing something? Do I need a solenoid for the suction lines as well for heating mode? Anyone done this before?